For a skimmer, the recommended mode is manual reset: the skimmer remains off after an alarm until the cause has been removed and the alarm has been reset.
Before you start
Always test detection and shut-off.
After installation, test the float switch, buzzer and actual skimmer shut-off.
Understand the 3 versions
Each version has a different role.
Physical float switch installation
Position the float before software settings.
Choose the position
Place the float where the maximum level should trigger the alarm, often in or near the collection cup.
Check movement
The float must move up and down freely without touching a wall or cable.
Check detection direction
If the alarm is reversed, flip the float on its shaft or change the signal setting.
Connect the sensor
Use only the intended CP-Safe input and do not force the connectors.
Float installation and wiring
Video references from the product guide.
CP-Safe setup
For CP-Safe only or the complete kit.
Power on CP-Safe
Wait 20 to 30 seconds after power-up.
Connect to its Wi-Fi
From a phone or PC, select the CP-Safe network.
Open the interface
Go to http://192.168.4.1. The “no Internet access” message is normal.
Choose the safety mode
For a skimmer, use manual reset mode: the socket remains off until Reset alarm has been pressed.
Quick troubleshooting
Simple checks before contacting support.
The socket does not turn back on after the test
In manual reset mode this is normal: remove the cause of the alarm, then press Reset alarm.
The alarm is reversed
Flip the float or change the HIGH/LOW setting in the interface.
CP-Safe does not switch off the skimmer
Check that you are using the kit with CP-Plug and test the complete wiring.
Safety checklist
Before leaving the skimmer unattended.
Check
- Float free and correctly oriented.
- 192.168.4.1 interface accessible.
- Manual reset mode configured for the skimmer.
- Actual skimmer shut-off tested.
Avoid
- Using CP-Safe alone while expecting it to switch the skimmer off directly.
- Ignoring a reversed float orientation.
- Putting the system back into service without a full test.